Table 4-53. Spcl > Servicing > Time Skew Adj > Submenu
Menu Item Function
(Type) Selections (SCPI cmd)
CH1 Skew Adj 0.0 to ± 99.9 nsec Adjust the time skew of channel 1
(Numeric)
Press the Spcl > Servicing > Time Skew > CH1 Skew Adj menu key to
display a menu to adjust the timing skew between channel 1 and the
trigger system time reference.
CH2 Skew Adj 0.0 to ± 99.9 nsec Adjust the time skew of channel 1
(Numeric)
Press the Spcl > Servicing > Time Skew > CH2 Skew Adj menu key to
display a menu to adjust the timing skew between channel 2 and the
trigger system time reference.